McLane Research Laboratories, Inc.
About McLane Research LabsMcLane Research Labs ProductsMcLane Research Labs ServicesContact McLane Research LabsMcLane Research Labs Announcements

Time-Series Zooplankton Sampler, ZPS 7-50

 
ZPS 7-50 Time-Series Zooplankton Samplers (ZPS 7-50) collect samples in either standard time-series or in action-trigger mode. A sample is collected using a specially designed positive displacement pump that generates negative pressure through a dome-shaped intake. The zooplankton are transported onto a 3.5 x 6 cm frame of a special roll of Nitex mesh. Up to 250 liters of water can be filtered through each frame of mesh. The Zooplankton retained on the sample frame are sandwiched by another layer of Nitex mesh for protection and immediately moved to the fixative bath for storage until recovery of the sampler.

A new frame of mesh is positioned automatically for the next sampling cycle. This procedure can be repeated up to 50 times for each roll of Nitex mesh as. Upon recovery, the Nitex mesh roll is removed from the fixative tank and the zooplankton on each frame can be examined. This sampling process is analogous to a roll of photographic film in a camera which is wound up into a cartridge until developed.

The standard frame is 316SS weldment which allows the sampler to be attached to a mooring.

Physical Configuration
Height 92 cm
Diameter 82 cm
Weight in air 102 Kg
Weight in water 68 Kg
Maximum depth 5,000 m
Collector Configuration
Max. number of samples 50
Frame mesh Nitex 50 to 500 µm
Frame area 3.5 x 6 cm
Protective second mesh Nitex 50 to 500 µm
Recommended fixative Glutaraldehyde/sea water buffer in the take up reel tank
Cleaning of frames Sea water back-flush
Collector materials Acrylic and Acetal block
Pump
Flow rate 15 to 25 l/min.
Maximum total volume 25,000 liters
Recommended vol./sample 250 liters
Type of pump McLane 30 L/min pump
Volume error Average ± 5%
Controller/Battery
Communications Serial (RS-232)
Main battery 36 VDC 42 Ah alkaline battery pack
Pressure Case Aluminium, 6061-T6 hardcoat anodized
Frame
Material 316SS
Structure Weldment
Duration of Deployment
3 months or longer, depending upon bio-fouling situation
Options
External sensors including current meter, transmissometer, or other analog sensor may be integrated
 
Specifications Subject to Change Without Notice
 
Home | About Us | Products | Services | News | Support | Contact/Reply
McLane Research Laboratories, Inc Falmouth Technology Park
121 Bernard E. Saint Jean Drive East Falmouth, MA 02536
Tel: 508.495.4000   Fax: 508.495.3333